Virtual Private Networks (VPN) OpenVPN
IX30 User Guide
406
Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX30
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Use the add auth group command to add a new authentication. For example, to add a group
named OpenVPN_Group:
(config)> add auth group OpenVPN_Group
(config auth group OpenVPN_Group)>
4. Enable OpenVPN access rights for users of this group:
(config auth group OpenVPN_Group)> acl openvpn enable true
5. Add an OpenVPN tunnel to which users of this group will have access:
a. Determine available tunnels:
(config auth group OpenVPN_Group)> .. .. .. vpn openvpn server ?
Servers: A list of openvpn servers
Additional Configuration
---------------------------------------------------------------------
----------
OpenVPN_server1 OpenVPN server
(config auth group OpenVPN_Group)>
b. Add a tunnel:
(config auth group OpenVPN_Group)> add auth group test acl openvpn
tunnels end /vpn/openvpn/server/OpenVPN_server1
(config auth group OpenVPN_Group)>
6. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
7. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals