Services Location information
IX30 User Guide
558
v. A sandbox is enabled by default to prevent the script from adversely affecting
the system. To disable the sandbox:
(config service location geofence test_geofence on_entry
action 0)> sandbox false
(config service location geofence test_geofence on_entry
action 0)>
If you disable the sandbox, the script may render the system unusable.
vi. Repeat for any additional actions.
n
To define actions that will be taken when the device exits the geofence, or is outside the
geofence when it boots:
a. (Optional) Configure the device to preform the actions if the device is outside the
geofence when it boots:
(config)> service location geofence test_geofence on_exit bootup
true
(config)>
b. Set the number of update_intervals that must take place prior to performing the
actions:
(config)> service location geofence test_geofence on_exit num_
intervals int
(config)>
For example, if the update interval is 1m (one minute) and the num_intervals is set
to 3, the actions will not be performed until the device has been outside the
geofence for three minutes.
c. Add an action:
i. Type ... to return to the root of the configuration:
(config service location geofence test_geofence coordinates
3)> ...
(config)>
ii. Add the action:
(config)> add service location geofence test_geofence on_exit
action end
(config service location geofence test_geofence on_exit
action 0)>
d. Set the type of action:
(config service location geofence test_geofence on_exit action
0)> type value
(config service location geofence test_geofence on_exit action
0)>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals