Digital Input/Output and Analog Input Send digital and analog I/O monitoring information to a remote server
IX30 User Guide
835
Web
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
a. Locate your device as described in Use Digi Remote Manager to view and manage your
device.
b. Click the Device ID.
c. Click Settings.
d. Click to expand Config.
Local Web UI:
a. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click I/O > Monitoring.
4. Click to expand Server.
5. For Add Server, type a name of the server and click .
6. For Address, type the hostname or IPv4 address of the server.
7. For Port, type the port on the remote server where the monitoring information should be sent.
8. For Communication protocol, select TCP or UDP.
9. For Polling period, type or select the interval, in seconds, that the device will use to upload
I/O information to the remote server.
10. Repeat these steps for additional remote monitoring servers.
11. Click Apply to save the configuration and apply the change.
Command line