Digital Input/Output and Analog Input Send digital and analog I/O monitoring information to a remote server
IX30 User Guide
836
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX30
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Add a remote server:
(config)> add io monitoring sever name
(config io monitoring server name)>
4. Set the hostname or IPv4 address of the server:
(config io monitoring server name)> address IPv4_address
(config io monitoring server name)>
5. Set the port on the remote server where the monitoring information should be sent:
(config io monitoring server name)> port port
(config io monitoring server name)>
6. Set the protocol:
(config io monitoring server name)> protocol value
(config io monitoring server name)>
where value is either tcp or udp. tcp is the default.
7. Set the interval, in seconds, that the device will use to upload I/O information to the remote
server:
(config io monitoring server name)> polling_period int
(config io monitoring server name)>
The default is one second.
8. Repeat for each additional remote server.
9. Save the configuration and apply the change:
(config io monitoring server name)> save
Configuration saved.
>
10. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals