This command can be used to configure HA settings for Vigor routers.
S
S
y
y
n
n
t
t
a
a
x
x
ha set [-<command> <parameter>| ... ]
S
S
y
y
n
n
t
t
a
a
x
x
D
D
e
e
s
s
c
c
r
r
i
i
p
p
t
t
i
i
o
o
n
n
Parameter Description
[<command>
<parameter>|…]
The available commands with parameters are listed below.
[…] means that you can type in several parameters in one
line.
-e <1/0>
1: Enable the function of High Availability (HA).
0: Disable the function of High Availability (HA).
-l <1/0>
1: Enable the function of recording the operation record of
HA in Syslog.
0: Disable the function of recording the operation record of
HA in Syslog.
-M <1/0>
Specify the Redundancy Method for HA.
1: Active-Standby
0: Hot-Standby
-v <1-255>
Specify the group ID (VHID)
1- 255: Setting range.
-R
Set HA settings to Factory Default.
-p <1-30>
Specify the Priority ID.
1-30: Setting range.
-k <key>
Specify the Authentication Key.
Key: Max. 31 Characters.
-u <1/0>
Enable or disable the function of Update DDNS.
1: Enable. When a router changes HA status to primary, it
will update DDNS automatically.
0: Disable.
-m <interface>
Specify the management interface.
Interface: LAN1 ~ LAN5, DMZ.
-s
It means to get the newest status of other router (except the
local router).
-y
It means sync local config to other router. Primary can
executes this command. Secondary can not execute this
commad.
-c <1/0>
Enable or disable the function of Config Sync.
1: Enable.
0: Disable.
-I -[M|H|D] <interval>
Set the Config Sync Interval for HA. Minimum interval is 15
minutes.
-M: Minute. Setting range is 0/15/30/45. (e.g., ha set -I -M
30)
-H: Hour. Setting range is from 0 to 23. (e.g., ha set -I -H 12)
-D: Day. Setting range is from 0 to 30. (e.g., ha set -I -D 15)