Parameter
Lowest (Minimum) Forward Speed
Lowest (Minimum) Reverse Speed
6.1.1.2 Non-profiled
The parameters that are not in the Drive Profiles can be adjusted in the Non-Profiled menu.
Figure 35: Non-profiled menu
1. In the Main Menu screen, press PROG to enter the Programming Menu.
2. To select Non-Profiled, press NEXT twice and then press EDIT.
3. Press NEXT until the desired parameter is shown.
4. Press UP or DOWN to adjust the parameter to the desired value. Please note that
each change is effective immediately, there is no option to cancel a change. To undo
a change, manually set the parameter back to its original setting with UP or DOWN.
5. Press EXIT twice to return to the Main Menu.
In the Non-Profiled Menu, the following parameters can be adjusted:
Parameter
Sleep Timer
Enable Beeper
Swap Throttle Direction
BatGauge Sensitivity
Service Scheduler
Flash Code Beeper
Sleep Beeper (Beep on Sleep)
Reversing Beeper
Motion Beeper
6.1.1.3 Throttle calibration
The throttle calibration automatically detects and sets the correct values for the Swap
Throttle Direction, Throttle Neutral Offset, Minimum Throttle Voltage and Maximum Throttle
Voltage parameters.
Note
The HHP can only calibrate the throttle if there are no faults active, including throttle faults and OONAPU (Out
Of Neutral At Power Up) faults that are caused by a faulty calibration.
GBK51948 RHINO2
Installation Manual Issue 5
Programming - Page 59