Appendix WinAQMS Mini DAS User manual 1.0
84
WinAQMS Mini DAS std.
<PPP>,<RRR>,<YYYY/MM/DD HH:NN:SS>,<CH#>,<0.####>,<status>,<CH#>,<0.####>,<status>,....<CR><LF>
PPP - is the data file prefix (1 to 3 character length)
, - comma character (A.S.C.I.I. 44)
RRR - is the report number (1 to 3 character length) where:
1 = report 1
2 = report 2
3 = report 3
4 = report 4
128 = span report
144 = zero report
160 = precision report
YYYY/MM/DD HH:NN:SS - is the date and time
CH# - the channel number
0.#### - channel data in standard numerical format with the number of decimal places specified in
WinAQMS Mini DAS.
status - data status (see section 8 Appendix D for more information on the WinAQMS Mini DAS
status)
CR carriage return character (A.S.C.I.I. 13)
LF linefeed character (A.S.C.I.I. 10)
Mantacom
The Mantacom format is a 3
rd
party format used by specific customers. The entire message is 85
characters long including the carriage return (CR) and linefeed (LF) characters and is space filled
if required.
<HH:MM:SS><sp><0.####><sp><0.####><sp>…<sp><CR><LF>
HH:MM:SS time of the data reading
sp space character (A.S.C.I.I. 32)
0.#### - channel data is standard numerical format with the number of decimal places specified in
WinAQMS Mini DAS
CR carriage return character (A.S.C.I.I. 13)
LF linefeed character (A.S.C.I.I. 10)