Configuring Event Logging
– 419 –
◆ RAM Level – Limits log messages saved to the switch’s temporary RAM
memory for all levels up to the specified level. For example, if level 7 is
specified, all messages from level 0 to level 7 will be logged to RAM.
(Range: 0-7, Default: 7)
N
OTE
:
The Flash Level must be equal to or less than the RAM Level.
N
OTE
:
All log messages are retained in RAM and Flash after a warm restart
(i.e., power is reset through the command interface).
N
OTE
:
All log messages are retained in Flash and purged from RAM after a
cold restart (i.e., power is turned off and then on through the power
source).
WEB INTERFACE
To configure the logging of error messages to system memory:
1. Click Administration, Log, System.
2. Select Configure Global from the Step list.
3. Enable or disable system logging, set the level of event messages to be
logged to flash memory and RAM.
4. Click Apply.
Figure 229: Configuring Settings for System Memory Logs
To show the error messages logged to system or flash memory:
1. Click Administration, Log, System.
2. Select Show System Logs from the Step list.
1 Alert Immediate action needed
0 Emergency System unusable
Table 24: Logging Levels (Continued)
Level Severity Name Description
* There are only Level 2, 5 and 6 error messages for the current firmware release.