The following configuration examples are provided for a Linux-based DHCP
daemon (dhcpd.conf file). In the “Vendor class” section, the server will
always send Option 66 and 67 to tell the switch to download the “test”
configuration file from server 192.168.255.101.
ddns-update-style ad-hoc;
default-lease-time 600;
max-lease-time 7200;
log-facility local7;
server-name "Server1";
Server-identifier 192.168.255.250;
#option 66, 67
option space dynamicProvision code width 1 length 1 hash size 2;
option dynamicProvision.tftp-server-name code 66 = text;
option dynamicProvision.bootfile-name code 67 = text;
subnet 192.168.255.0 netmask 255.255.255.0 {
range 192.168.255.160 192.168.255.200;
option routers 192.168.255.101;
option tftp-server-name "192.168.255.100"; #Default Option 66
option bootfile-name "bootfile"; #Default Option 67
}
class "Option66,67_1" { #DHCP Option 60 Vendor class two
match if option vendor-class-identifier = "ecs3510-28t.cfg";
option tftp-server-name "192.168.255.101";
option bootfile-name "test";
}
N
OTE
:
Use “ecs3510-28t.cfg” for the vendor-class-identifier in the
dhcpd.conf file.
ENABLING SNMP
MANAGEMENT ACCESS
The switch can be configured to accept management commands from
Simple Network Management Protocol (SNMP) applications such as
Edge-Core ECView Pro. You can configure the switch to respond to SNMP
requests or generate SNMP traps.
When SNMP management stations send requests to the switch (either to
return information or to set a parameter), the switch provides the
requested data or sets the specified parameter. The switch can also be
configured to send information to SNMP managers (without being
requested by the managers) through trap messages, which inform the
manager that certain events have occurred.
The switch includes an SNMP agent that supports SNMP version 1, 2c, and
3 clients. To provide management access for version 1 or 2c clients, you
must specify a community string. The switch provides a default MIB View
(i.e., an SNMPv3 construct) for the default “public” community string that
provides read access to the entire MIB tree, and a default view for the

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS3510-28T and is the answer not in the manual?

Edge-Core ECS3510-28T Specifications

General IconGeneral
BrandEdge-Core
ModelECS3510-28T
CategoryNetwork Router
LanguageEnglish

Related product manuals