DCM00044 REV. 14 45
some cases, remote operation from a User I/O or a Remote Terminal can be used to solve
a distance limitation.
4.5.3 Input Power (Main)
The system requires single-phase input power, which you connect to the Power Supply
using the integral power cord. See Table 4.4
for plug and receptacle requirements for your
specific power level.
Refer to the unit’s Model Data Tag to be sure of the power rating of the Model in your
system.
4.5.4 Output Power (RF Cable)
Ultrasonic Energy is delivered to a screw-on MS receptacle connection on the rear of the
Power Supply, which is connected to the Ultraweld L20 Actuator.
4.5.5 Interconnect Between Power Supply and Actuator
The Ultraweld L20 Actuator has three electrical connections between the Power Supply
and the Actuator: the RF Cable, the Analog Data Cable, and the Control Cable.
There can be other connections to the Actuator, and other connections to the Power
Supply, but these are the three standard connections, depicted in Figure 4.7
.
WARNING General Warning
Never operate the System with the RF Cable disconnected or if the RF
Cable is damaged.