Menu 9
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
176 Unidrive SP Advanced User Guide
www.controltechniques.com Issue Number: 10
9.29 Binary sum ones input
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Default
Open-loop, Closed-loop vector, Servo,
Regen
0
Update rate 4ms x number of menu 9 or 12 functions active read
9.30 Binary sum twos input
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Default
Open-loop, Closed-loop vector, Servo,
Regen
0
Update rate 4ms x number of menu 9 or 12 functions active read
9.31 Binary sum fours input
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Default
Open-loop, Closed-loop vector, Servo,
Regen
0
Update rate 4ms x number of menu 9 or 12 functions active read
9.32 Binary sum output
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111 1
Range
Open-loop, Closed-loop vector, Servo,
Regen
0 to 255
Default
Open-loop, Closed-loop vector, Servo,
Regen
0
Update rate 4ms x number of menu 9 or 12 functions active write
9.33 Binary sum destination
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
1 2 1111
Range
Open-loop, Closed-loop vector, Servo,
Regen
Pr 0.00 to Pr 21.51
Default
Open-loop, Closed-loop vector, Servo,
Regen
Pr 0.00
Update rate Read on reset