Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menus 15 to 17
SM-I/O Lt Tmr
Unidrive SP Advanced User Guide 301
Issue Number: 10 www.controltechniques.com
This parameter defines the parameter to be represented by the status relay. Only unprotected parameters can be selected as a source for the relay
output. If a non-valid parameter is programmed, then the relay will remain in the last known state.
0: Real time clock parameters controlled by real time clock
1: Real time clock parameters controlled by user
2: Real time clock reads real time clock parameters and sets Pr x.30 to 0
This parameter is not available on the SM-I/O Lite.
Pr x.34 to Pr x.37 are not available on the SM-I/O Lite.
x.27 Terminal T21 / T23 relay/ source
RW Uni DE PT US
Ú
Pr 0.00 to Pr 21.51
Ö
Pr 0.00
Update rate: Read on drive reset
x.30 Real time clock update mode
RW Uni
Ú
0 to 2
Ö
0
Update rate: Background read/write
x.34 Real time clock minutes/seconds
RW Uni PT
Ú
00.00 to 59.59
Ö
00.00
Update rate: Background read/write
x.35 Real time clock days/hours
RW Uni PT
Ú
1.00 to 7.23
Ö
0.00
Update rate: Background read/write
x.36 Real time clock month/ date
RW Uni PT
Ú
00.00 to 12.31
Ö
00.00
Update rate: Background read/write
x.37 Real time clock years
RW Uni PT
Ú
2000 to 2099
Ö
2000
Update rate: Background read/write
NOTE