Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menus 15 to 17
SM-Applicat’ns
Unidrive SP Advanced User Guide 335
Issue Number: 10 www.controltechniques.com
This parameter is dependant on what is running in the module i.e. Indexer
Specifies the DPL program line number that caused a run-time error. This is valid only when:
The user program has been compiled with the debug option set
The error is one that can be generated by user code, for example divide by zero (50) or parameter does not exist (41).
If both of these conditions are not met, the line number parameter will display zero (0).
This parameter is available for the user to put in an ID code of their program. This may, for example, be the software version number. Use the function
block SETUSERID() to write to this parameter.
When a run-time error occurs the error number is placed into this parameter. (See Table 5-35 on page 327 for the meaning of the values in this
parameter).
See the Applications Modules User Guide for further information.
Specifies the minor revision number of the operating system of the Applications module. Use in conjunction with Pr x.02 to form the complete version
number.
x.47 User Set-Up Parameter 3
Access RO Range N/A
Default 0 Update Rate N/A
x.48 Line Number of Error
♦♣♥
Access RO Range 32 bit
Default 0 Update Rate On error
x.49 User program ID
♦♣♥
Access RO/RW Range Signed 16-bit
Default 0 Update Rate See Note
x.50 Run-time Error Code
♦♣♥
Access RO Range 0 to 255
Default 0 Update Rate On error
x.51 Firmware - Minor Version
♦♣♥
Access RO Range 0 to 99
Default N/A Update Rate N/A