Loading...
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Unidrive SP Advanced User Guide 377
Issue Number: 10 www.controltechniques.com
Ramps
Acceleration
rate
Deceleration
rate
Ramp mode
selector
S-ramp
enable
S-ramp
da/dt limit
Speed-loop
proportional
gain
Motor speed
0.03
0.04
0.15
0.18
0.19
Pre-ramp
reference
Post-ramp
reference
0.11 0.12
S-ramp
0.07
Speed-loop
integral gain
0.08
Speed-loop
derivative
gain
0.09
0.10
Voltage
mode
selector
Dynamic V/f
0.07
Boost
voltage
0.08
0.09
OL>
Motor-voltage
control
Estimated
motor
speed
0.10
Motor
active-current
PWM switching
frequency
0.41
0.13
Power
stage
select
CL>
Speed-loop
PID gains
OL> FREQUENCY
CL> SPEED
TORQUE
_
0.38
Current loop
Current
loop P gain
0.39
Current
loop I gain
Motor control
Current
limit
Rated rpm
autotune
0.33
0.06
No. of poles
Power factor
Rated voltage
Rated speed
Rated current
Rated frequency
0.42 to 0.47
Motor parameters
VT>
OL & VT>
Encoder phase angle
Rated voltage
Thermal time constant
Rated current
Rated frequency
SV>
No. of poles
Catch a
spinning motor
OL>
0.16
Stop
mode
selector

Table of Contents