Operation Proline Prowirl F 200 PROFIBUS PA
128 Endress+Hauser
Flow velocity
Temperature
Calculated saturated steam pressure
Steam quality
Total mass flow
Condensate mass flow
Energy flow
Heat flow difference
Reynolds number
Density
Specific volume
Pressure
Compressibility factor
Degrees of superheat
Parameter overview with brief description
Parameter Prerequisite Description User interface
Volume flow Displays the volume flow currently
measured.
Dependency
The unit is taken from the Volume flow
unit parameter
Signed floating-point
number
Corrected volume flow Displays the corrected volume flow
currently calculated.
Dependency
The unit is taken from: Corrected
volume flow unit parameter
Signed floating-point
number
Mass flow Displays the mass flow currently
calculated.
Dependency
The unit is taken from the Mass flow
unit parameter
Signed floating-point
number
Flow velocity Displays the flow velocity currently
calculated.
Dependency
The unit is taken from the Velocity
unit parameter
Signed floating-point
number

Table of Contents