Proline Promag H 300 PROFINET Technical data
Endress+Hauser 201
Nominal diameter Weight
[mm] [in] [kg] [lbs]
2 1/12 4.7 10.4
4 5/32 4.7 10.4
8 5/16 4.7 10.4
15 ½ 4.6 10.1
25 1 5.5 12.1
40 1 ½ 6.8 15.0
50 2 7.3 16.1
65 8.1 17.9
80 3 8.7 19.2
100 4 10.0 22.1
125 5 15.4 34.0
150 6 17.8 39.3
Measuring tube
specification
Nominal diameter Pressure rating
1)
Process connection internal diameter
EN (DIN) PFA
[mm] [in] [bar] [mm] [in]
2 1/12 PN 16/40 2.25 0.09
4 5/32 PN 16/40 4.5 0.18
8 5/16 PN 16/40 9.0 0.35
15 ½ PN 16/40 16.0 0.63
1 PN 16/40 22.6 0.89
25 PN 16/40 26.0 1.02
1) Depending on process connection and seals used
Materials Transmitter housing
Order code for "Housing":
Option A "Aluminum, coated": aluminum, AlSi10Mg, coated
Option B "Stainless, hygienic": stainless steel, 1.4404 (316L)
Window material
Order code for "Housing":
Option A "Aluminum, coated": glass
Option B "Stainless, hygienic": polycarbonate
Seals
Order code for "Housing":
Option B "Stainless, hygienic": EPDM and silicone
Cable entries/cable glands