C8-B/C12-B Service Manual Maintenance Disclosure Scope: Maintenance Trained Personnel Only
(C) Seiko Epson Corporation 2-190 Rev.1
Install the Air Tube.
1. Use an 8-mm wrench to rotate the part shown in the figure, and install the metal fitting.
POINT
• Install in front of the Motor Unit.
• After tightening by hand, further tighten one sixth to quarter of a turn.
CAUTION
• Excessive tightening may result in air leakage due to connector breakage or gasket
deformation.
• Insufficient tightening may result in air leakage due to connector breakage or gasket
deformation.