C8-B/C12-B Service Manual Maintenance Disclosure Scope: Maintenance Trained Personnel Only
(C) Seiko Epson Corporation 2-190 Rev.1
Install the Air Tube.
1. Use an 8-mm wrench to rotate the part shown in the figure, and install the metal fitting.
POINT
Install in front of the Motor Unit.
After tightening by hand, further tighten one sixth to quarter of a turn.
CAUTION
Excessive tightening may result in air leakage due to connector breakage or gasket
deformation.
Insufficient tightening may result in air leakage due to connector breakage or gasket
deformation.
2. Install the Air Tube.
3
Fitting
Nut
Air Tube
Installing the Motor Unit
5
3
1
4
6
6