C8-B/C12-B Service Manual Adjustment Disclosure Scope: Maintenance Trained Personnel Only
(C) Seiko Epson Corporation 3-18 Rev.1
4-5.Perform the calibration.
Execute one of the following commands to reset the encoder of the joint you want to calibrate from the menu-[Tool]-[Command Window].
Joint #1 >calib 1
Joint #2 >calib 2
Joint #3 >calib 3
Joint #4 >calib 4
Joint #5 >calib 5,6
Joint #6 >calib 6
NOTE
Warning 590 (Detect the different of the calibration settings in the controller and Safety Board) occurs when the
Calib command are executed.
Warning 590 is cleared by updating the Hofs value in the safety board.