SC-F2000 Revision C
ADJUSTMENT Electrical Component Adjustments 284
Confidential
[Blue]: Button or menu name on the program screen / [Black]: Button or menu name on the operation panel of the printer
4.14.12 Value Reset
Perform if the following happens and the correction value becomes abnormal after the
motor is replaced.
A fatal error occurs when restarting the printer after Motor Measurement.
Motor Measurement & Automatic Adjustment has been carried out when the
inside of the printer is contaminated with ink mist.
EXECUTION MODE
Normal Mode
PROCEDURE
1. Turn the printer ON.
2. Start the Service Program and select [XX Motor Value] of the target motor.
3. Click [RUN]. The correction value is reset.
4. When the message shown in Figure 4-100 appears after the adjustment is
completed, click [OK].
x
Figure 4-99. [Value Reset] Screen
Figure 4-100. Confirmation Screen
If you reset the correction value, carry out “4.14.11 Motor
Measurement & Automatic Adjustment” (p282) once again.