EasyManua.ls Logo

Ericsson AVP 4000 - Control Ethernet Connector

Ericsson AVP 4000
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing the Equipment
1/1553-FGC 101 1790 Uen Y
2-5
Table 2.2 Link Speed: Left (Green) LED
Link Speed LED Status
No Link Off
— — — — — — — — — — — — — — — — — —
100 Mbps Flash Off x 2
1000 Mbps Flash Off x 3
The left LED flash sequence period is 1 s, with a short flash duration of 100 ms.
Table 2.3 Link Activity: Right (Yellow) LED
Link Speed LED Status
No Link Off
— — — — — — — — — — — — — — — — — —
Link On
Activity Flash
2.3.3 Control Ethernet Connector
The Ethernet control ports are used to connect the
equipment to a PC for access with a web browser. Both
connectors share the same IP address, CTL 1 is the
Primary control port, and is by default the active control
port. Control Port CTL 2 should be considered as the
secondary control network as it will not respond to the
Control Port IP Address unless control has been passed
to it either as a result of a redundancy switch, or via a
user command. The active control port switches when
CTL 1 has no link (e.g. carrier), and CTL 2 has the link.
Table 2.4 Control Ethernet Connector
Item Specification
Connector type RJ-45 (100/1000 Base T)
Connector designation CTL 1
CTL 2
Pin outs
(Unused pins are not
connected)
Pin 1 - Tx Out (+)
Pin 2 - Tx Out (-)
Pin 3 - Rx In (+)
Pin 6 - Rx In (-)
Status and Activity Indication
Each Ethernet Control Port has rear panel mounted status LEDs to indicate link
status, activity and speed as follows: