EasyManua.ls Logo

Ericsson AVP 4000 - Fan(S) Not Working;Overheating; Fuse Replacement; Lithium Battery; Power Supply Problems;Unit Not Working

Ericsson AVP 4000
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preventive Maintenance and Fault-finding
1/1553-FGC 101 1790 Uen Y
8-11
8.5.3 Power Supply Problems/Unit Not Working
If the unit Status LED is unlit, fault-find the problem as detailed in Table 8.3.
Table 8.3 Status LED Unlit Fault-finding
Step Action If Result of Action is Yes… If Result of Action is No…
1
Is the LED/LCD display inactive
but the unit still working?
If the unit is clearly working
normally then the LED/LCD
Display itself is probably at
fault. Call a Service Engineer.
Proceed to next step.
2
Check Power Source. Connect
a known-working piece of
equipment to the power source
outlet. Does it work?
The problem lies within the
unit or power cable. Proceed
to next step.
The problem lies with the power
source. Check building circuit
breakers, fuse boxes, etc. If
problem persists, contact the
electricity supplier.
3
Check Power Cable and Fuse.
Unplug the power connector
from the unit and try it in another
piece of equipment. Does it
work?
The problem lies within the
unit. Proceed to next step.
The problem lies with either the
cable itself, or with the fuse in
the plug. Replace the fuse or try
to substitute another cable.
4
Check PSU Module(s) and
Fuse(s). Ensure the power
connector is unplugged.
Remove the fuse from the rear
panel connector and inspect it.
Has the fuse blown?
Replace the fuse with one of
the correct type and rating
(see Annex B Technical
Specification). If the PSU still
does not work, unplug the
power cable and call a Service
Engineer.
Possible problem with the PSU
module. Call a Service Engineer.
8.5.3.1 Fuse Replacement
Please refer to the Installation, Safety and Compliance Information for Ericsson
Compression Products Reference Guide supplied with your product for full details of
how to replace the fuse in your product.
8.5.3.2 Lithium Battery
The lithium battery fitted within this product is not user replaceable and as such
should only be replaced by qualified service personnel.
8.5.4 Fan(s) Not Working/Overheating
The fan speed can be reduced (set to lowest noise) at low temperatures to allow the
unit to quickly attain operational temperature. In the event of overheating problems,
refer to Table 8.4.
Note: Failure to ensure a free air-flow around the unit may cause overheating.
This condition is detected by a temperature sensor; it may be used to trigger
an automatic alarm.