Alarm Description Port Number Alarm ID Source Severity
POIS URL not configured
An Acquisition Point Identity is
already configured, but the POIS url
is empty. Signal Processing Events
can't be sent to POIS. Add a valid
POIS URL in the AVP 4000 UI.
0 0000045D Base Unit minor
Invalid POIS URL configured
The configured POIS url is not a
valid http url . Signal Processing
Events can't be sent to POIS.Correct
the POIS URL in the AVP 4000 UI.
0 0000045E Base Unit minor
POIS connection failure
The unit could not contact the POIS
Server. Check the POIS URL using
a tool like cURL.
0 0000045F Base Unit major
Invalid response from POIS
The POIS response xml does not
contain any valid response signal.
Analyse the POIS response XML.
0 00000460 Base Unit major
PCR Exchange message
timeout
PCR exchange message has not
arrived.
0 00000690
Reflex
controller
warning
Status message timeout Status message has not arrived. 0 00000691
Reflex
controller
warning
Reflex StatMux algorithm failed
Reflex statistical multiplexing
algorithm returned with an error.
0 00000692
Reflex
controller
warning
MGP Failure
Failed to go online, previous online
device preventing transmission
0 00000491 Base Unit major
MGP Collision
Potential duplicate transmission
detected
0 00000492 Base Unit major
MGP Spurious Spurious MSM packet detected 0 00000493 Base Unit minor
CSM Contact lost
No CSMs received from Control
System
0 00000680 Base Unit minor
Datagram loss is greater than 0
The datagram loss rate for the
Transport Stream is greater than 0.
1
000006B0 to
0000073F
Base Unit major
Sequence number errors in
Transport Stream
There are sequence number errors
in the Transport Stream.
1
000007B0 to
0000083F
Base Unit major
No data available for Input
Transport Stream
Both Primary and Backup Input
Transport Streams have failed.
1
00000500 to
0000057F
Base Unit critical
Input Transport Stream running
on Backup
Primary Input Transport Stream has
failed.
1
00000580 to
000005FF
Base Unit warning
Input Transport Stream missing Input Transport Stream has failed. 1
00000600 to
0000067F
Base Unit major
Excessive CC errors on PID
The PID monitor has detected
continuity count errors, which
exceed the windowed threshold.
0
0000BB0 to
0000C2F
Base unit major
PID on data input network is
missing
The PID monitor has detected a PID
missing for at least the period set by
the user.
0
0000B30 to
0000BAF
Base unit major