EasyManua.ls Logo

Ericsson AVP 4000 - Page 58

Ericsson AVP 4000
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Getting Started
3-22
1/1553-FGC 101 1790 Uen Y
4. The unit must be rebooted after configuring card roles. If the unit does not
automatically reboot, select Support > Device Management, and select the
Reboot Device button in the Reset Device panel.
Table 3.5 Configuration of Option Cards
Chassis Type of Services Slot Card Role
All types of Six Slot Chassis
One service comprising of ABR and
Multiplatform
4 ABR
5 Decode/Encode
6 Broadcast
All types of Six Slot Chassis One service comprising of ABR only 5 ABR
6 Decode/Encode
All types of Six Slot Chassis
Two services each comprising of ABR
only
3 ABR
4 Decode/Encode
5 ABR
6 Decode/Encode
AVP4000/BAS/1AC/ED
Two services each comprising of ABR
and Multiplatform
1 ABR
2 Decode/Encode
3 Broadcast
4 ABR
5 Decode/Encode
6 Broadcast
AVP4000/BAS/1AC/ED
Three services each comprising of
ABR only
1 ABR
2 Decode/Encode
3 ABR
4 Decode/Encode
5 ABR
6 Decode/Encode
AVP4000/BAS/2AC
One service comprising of ABR and
Multiplatform
1 ABR
2 Decode/Encode
3 Broadcast
AVP4000/BAS/2AC One service comprising of ABR only 3 ABR
4 Decode/Encode
AVP4000/BAS/2AC
Two services each comprising of ABR
only
1 ABR
2 Decode/Encode
3 ABR
4 Decode/Encode

Table of Contents