Getting Started
1/1553-FGC 101 1790 Uen Y
3-27
To set up an encode configuration:
1. Ensure the two cards to be used are numerically adjacent in the chassis. For
example, cards in slots 3 and 4 (any adjacent pairing may be used).
2. Plug the HD-SDI coaxial cable into the BNC connector on the lower numbered
slot. The data from this HD-SDI feed may be used by the card in the next
adjacent superior slot. For example, if the HD-SDI feed is on slot 3, then slot 4
may be set up to use the HD-SDI data from slot 3.
3. Set up the encode service for the lower-numbered slot as documented in section
3.7.5 How to Configure Output Transport Streams.
4. To set up the encode service for the higher-numbered slot, right-click on the
service, and select Add Additional Output Service > On Adjacent card (slot
4 ) > [encode type].
Figure 3.13 Adding Additional Output Service
5. When the new service has been created, modify and check all settings for all
components, and then click the Apply All button to save the changes made.
Note: Only incoming video with HD resolutions are supported for this use case.