• Conditional Access Table (CAT)
• Master Guide Table (MGT)
• System Time Table (STT)
• Terrestrial/Cable Virtual Channel Table (T/C)VCT
• Event Information Table (EIT)
Operation
To set up PSIP data insertion:
1. On the Service Configuration page, create the Transport Stream you want to
add the PSIP information to.
2. Add the required services and components, and adjust the Transport Stream
and component settings.
3. In the Outputs widget, select the Transport Stream you want to add the PSIP
data to. In the Properties widget, set Syntax to ATSC and the External
Generation to Off. The Program Specific Information and the PSIP
Information accordion panels are now displayed.
Note: If external table generation is enabled, the unit does not produce tables
internally.
4. By setting a table On, the appropriate parameters are displayed. To configure
PSIP data, set PAT/PMT to On. Set PMT Repetition Period as required. The
default value is 500 ms.
5. Conditional Access Table can be activated by setting CAT parameter to On.
6. By setting STT On, GPS UTC Offset and Daylight Saving can be configured.
7. By setting (T/C)VTC On, the following parameters can be configured: Delivery
(Terrestrial/Cable), Major Channel Number, Modulation Mode.
8. By turning EIT On, EIT Base PID and the number of the Event information
Tables can be set.