The tables to be included have to be set up on the Triveni Digital GuideBuilder
equipment. For the configuration of the Triveni Digital GuideBuilder refer to its user
manual.
Note: In general, all tables generated by Triveni Digital GuideBuilder will be
included in the output.
Operation
External PSIP data insertion requires a valid AVP/SWO/PSIP license be present on
the unit.
Note: If external table generation is enabled, the unit does not produce tables
internally.
To set up PSIP data insertion, follow the steps below:
1. On the Service Configuration page, create the Transport Stream you want to
add the external PSIP information to.
2. Add the required services and components, and adjust the Transport Stream
and component settings.
3. In the Outputs widget, select the Transport Stream you want to add the PSIP
data to. In the Properties widget, set Syntax to ATSC and the External
Generation to On - Triveni. The PSIP accordion panel is now displayed.
4. In the PSIP accordion panel, set the TCP Port to the port through which your
unit will communicate with the Triveni Digital GuideBuilder equipment. The
default port used by Triveni Digital GuideBuilder is 1250.
5. Set the Maximum PSIP bit rate as required. The more tables that are generated
by the Triveni Digital GuideBuilder, the higher the data rate.
Note: Once the Triveni Digital GuideBuilder has been set up and a communication
link between the Triveni and your unit is established, the actual bit rate will
be updated in the Real PSIP bit rate field.
6. If you want to generate STT, then set the STT Table Insertion option to On.
Note: The STT table itself is generated by the Triveni Digital GuideBuilder, and the
generated table is updated with the UTC time on the AVP 4000 unit. UTC
time can be configured by drilling down to Encoder > Base Unit in the
Advanced Video Processor Settings widget on the Advanced tab of the
Device Configuration page, and setting the correct UTC time and date in
the UTC Time and UTC Date fields in the Properties widget. A time server
can be set up in the SNTP Server field.
7. In the Minimum PID and Maximum PID fields, set the PID range for the
generated PSIP tables.
8. Configure the Triveni Digital GuideBuilder equipment as described in its user
manual. Make sure you apply the same Transport Stream and communication