EasyManuals Logo

Ethernet Direct Husky HMG-1648P User Manual

Default Icon
213 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
PTP (IEEE1588)
HMG-838PT & HMG-838EPT Web Configuration 21-3
6 (Currently the clock Accuracy is set to 'Unknown' as default).
Pri1: Configure Clock priority 1 used by the BMC master select algorithm. The valid value is from 0 to 255.
Pri2: Configure Clock priority 2 used by the BMC master select algorithm. The valid value is from 0 to 255.
Protocol: This shows transport protocol used by the PTP protocol engine.
One-Way: If true, one way measurements are used. This parameter applies only to a slave. In one-way mode no
delay measurements are performed, i.e. this is applicable only if frequency synchronization is needed. The master
always responds to delay requests.
VLAN Tag Enable: This shows whether VLAN tagging for the PTP frames is enabled (True) or not (False).
VID: This shows VLAN Identifier used for tagging the VLAN packets.
PCP: This shows Priority Code Point value used for PTP frames.
Clock current Data Set: The clock current data set is defined in the IEEE 1588 Standard. The current data set is
dynamic
stpRm: This stands for “Steps Removed” and is the number of PTP clocks traversed from the grandmaster to the
local slave clock.
Offset from master: This shows time difference between the master clock and the local slave clock, measured in
ns.
Mean Path Delay: this show the mean propagation time for the link between the master and the local slave.
Filter Parameters
DelayFilter, Period, Dist: The default delay filter is a low pass filter, with a time constant of
2**DelayFilter*DelayRequestRate. The default offset filter uses a minimum delay filter method i.e. The minimum
measured offset during Period samples is used in the calculation. The distance between two calculations is Dist
periods.
Clock Parent Data Set: The clock parent data set is defined in the IEEE 1588 standard. The parent data set is
dynamic.
Parent Port Identity: This shows Clock identity for the parent clock, if the local clock is not a slave, the value is
the clocks own id.
Port: This shows port ID for the parent master port.
PStat: Parents Stats (always false).
Var: It is observed parent offset scaled log variance.
Change Rate:
Observed Parent Clock Phase Change Rate. i.e. the slave clo
cks rate offset compared to the
master. (unit = ns per s).
Grand Master Identity: Clock identity for the grand master clock, if the local clock is not a slave, the value is the
clocks own id.
Grand Master Clock Quality: The clock quality (Clock Class, Clock Accuracy and OffsetScaledLog Variance)
announced by the grand master.
Pri1: Clock priority 1 announced by the grand master.
Pri2: Clock priority 2 announced by the grand master.
Clock Time Properties Data Set: The clock time properties data set is defined in the IEEE 1588 Standard. The data
set is both configurable and dynamic, i.e. the parameters can be configured for a grandmaster. In a slave clock the
parameters are overwritten by the grandmasters timing properties. The parameters are not used in the current PTP
implementation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ethernet Direct Husky HMG-1648P and is the answer not in the manual?

Ethernet Direct Husky HMG-1648P Specifications

General IconGeneral
BrandEthernet Direct
ModelHusky HMG-1648P
CategoryNetwork Router
LanguageEnglish

Related product manuals