EasyManua.ls Logo

EUCHNER MSC - 8.4.2. Module FI8 FO2 (Figure 28)

EUCHNER MSC
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Modular Safety Control System MSC
54
(Translation of the original operating instructions) 2121331-04-04/19
8.4.2. Module FI8FO2 (Figure 28)
MEANING
LED
RECTIFICATION MEASURE
RUN
GREEN
IN FAIL
RED
EXT FAIL
RED
SEL
ORANGE
IN1–8
YELLOW
OSSD1/2
RED/GREEN
CLEAR1/2
YELLOW
STATUS1/2
YELLOW
Internal error OFF
Flashes 2 or 3
times
OFF
Indicates
the physical
address of the
module
OFF Red OFF OFF
Ì Send module to EUCHNER
for repair
Compatibility error OFF
Flashes 5
times
OFF
Flashes 5
times
Flashes 5 times
Flashes 5
times
Flashes 5
times
Ì Firmware version not com-
patible with MSC-CB. Send
to EUCHNER for firmware
upgrade.
OSSD output error OFF
Flashes 4
times
OFF OFF
Flashes 4 times
(only the LED
corresponding
to the output in
the error mode)
OFF OFF
Ì Check OSSD1/2 connections
Ì If the problem persists, send
FI8FO2 to EUCHNER for
repair.
Error during communi-
cation with base unit
OFF
Flashes 5
times
OFF OFF OFF OFF OFF
Ì Restart system.
Ì If the problem persists, send
FI8FO2 to EUCHNER for
repair.
Error in another
extension module or
MSC-CB
OFF ON OFF OFF OFF OFF OFF
Ì Restart system.
Ì Check which module is in the
ERROR mode.
Extension module of
the same type with
the same address
detected
OFF
Flashes 5
times
Flashes 5
times
OFF OFF OFF OFF
Ì Change address of the mod-
ule (see section NODE_SEL)
Internal node detection
error
OFF
Flashes 3
times
OFF
RECTIFICATION
MEASURE
OFF OFF OFF OFF Ì Send to EUCHNER for repair.
Table 47: Troubleshooting FI8FO2
Figure 28:
FI8FO2

Table of Contents

Other manuals for EUCHNER MSC