EasyManua.ls Logo

EUCHNER MSC - 8.4.6. Modules AC-FO2;AC-FO4 (Figure 32)

EUCHNER MSC
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Modular Safety Control System MSC
58
(Translation of the original operating instructions) 2121331-04-04/19
8.4.6. Modules AC-FO2/AC-FO4 (Figure 32)
MEANING
LED
RECTIFICATION MEASURE
RUN
GREEN
IN FAIL
RED
EXT FAIL
RED
SEL
ORANGE
OSSD1/2
RED/GREEN
CLEAR1/2
YELLOW
STATUS1/4
YELLOW
Internal error OFF
Flashes 2 or
3 times
OFF
Indicates
the physical
address of
the module
Red OFF OFF
Ì Send module to EUCHNER for
repair.
Compatibility error OFF
Flashes 5
times
OFF
Flashes 5
times
Flashes 5
times
Flashes 5
times
Ì Firmware version not compatible
with MSC-CB. Send to EUCHNER
for firmware upgrade.
OSSD output error OFF
Flashes 4
times
OFF
Flashes 4
times
(only the LED
corresponding
to the output
in the error
mode)
OFF OFF
Ì Check OSSD1/2 connections.
Ì If the problem persists, send
AC-FO2/AC-FO4 to EUCHNER for
repair.
Error during communica-
tion with base unit
OFF
Flashes 5
times
OFF OFF OFF OFF
Ì Restart system.
Ì If the problem persists, send
AC-FO2/AC-FO4 to EUCHNER for
repair.
Error in another extension
module or MSC-CB
OFF ON OFF OFF OFF OFF
Ì Restart system.
Ì Check which module is in the
ERROR mode.
Extension module of the
same type with the same
address detected
OFF
Flashes 5
times
Flashes 5
times
OFF OFF OFF
Ì Change address of the module
(see section NODE_SEL)
Power supply failed on
OSSD3/4 (only AC-FO4)
ON OFF ON Red ashing Flashing
OUTPUT
state
Ì Connect terminal 13 and 14 to
power supply
STATUS output overload
or short circuit
OFF OFF ON OSSD state CLEAR state Flashing Ì Check STATUS cable
Internal node detection
error
OFF
Flashes 3
times
OFF
Flashes 3
times
OFF OFF OFF Ì Send to EUCHNER for repair.
Table 51: Troubleshooting AC-FO2/AC-FO4
Figure 32:
AC-FO2/AC-FO4

Table of Contents