12 02-2023 6095 00
To clean the mixers, act as follows:
1. open the cover of mixers and lift the pow-
der ports as far as the retainer;
2. detach the instant drink tube from the
water funnel connection
3. rotate the ring nut intended to fasten the
water funnel counterclockwise and re-
move the mixer from the machine
4. separate all components (the funnels of
instant products, water funnels, convey-
ors, powder deposit drawers)
5. remove the mixer impeller;
Fig. 10
6. dip the components into a container with
the sanitising solution you have prepared
before for about 20 minutes, wash and
make sure that you have mechanically
removed visible residues and films by
using, if necessary, pipe cleaners or
brushes;
7. re-assemble the impellers
8. re-position the mixer.
Make sure that the water funnel is prop-
erly inserted.
9. rotate the ring nut intended to fasten the
water funnel clockwise to secure the
mixer to the machine
after having assembled the parts, act
as follows, any way:
-wash the mixers and add some drops of
the sanitising solution into the various fun-
nels.
-rinse the parts abundantly to remove any
residue of the solution in use.
All the operations requiring the ma-
chine to be directly connected to a
source of electricity must be ONLY car-



Table of Contents