02-2023 6095 00 77
FAN REPLACEMENT
The steam suction fan is accessed from the
inside of the machine.
If it should be necessary to act on the fan
for any reason, remove the instant canisters
from the machine and the cover.
Important!!!
Remove the covers after detaching the
device from the mains.
Fig. 53
1. Steam suction fan
2. Instant mixer
3. Instant mixer cover
BOILER HEAT PROTECTION
The boiler/s is/are protected against over-
heating by a safety thermostat disabling the
boiler heating element in case of a failure in
the boiler control system.
The thermostat trips if the internal water
temperature should exceed the safety
threshold.
If the thermostat trips, wait for the
boiler to cool down before nding out
the reason for the failure and manually
resetting the thermostat.
Important!!!
If the safety thermostat should trip, replace
the boiler temperature probe and the gas-
kets of the unions on the boiler since they
may be irreversibly damaged.
coffEE boilEr
A safety thermostat is arranged on the cof-
fee boiler to stop the power supply of the
heating element if the boiler should reach
and exceed the temperature of 125°C.
To reset the thermostat:
1. Open the espresso shelf
2. Press the button to reset the thermostat
3. Re-close the espresso shelf
Fig. 54