20 02-2023 6095 00
ovErflow DEvicE
The water inlet solenoid valve is complete
with an overow device that can mechani-
cally lock the water inlet as a result of a
malfunction of the solenoid valve or the
water level control gear.
To restore the normal operation, act as fol-
lows:
1. discharge water in the overflow tube;
2. close the water network tap outside the
machine;
3. loosen the union intended to fasten the
supply tube of the solenoid valve to
discharge the residual network pressure
and tighten it again.
4. open the tap and power on the machine.
from tHE taNk
Models with tank only
Use the self-supply kit specic for the de-
vice; the kit is supplied with mounting and
testing instructions that shall be strictly fol-
lowed to preserve the machine safety.
Important!!
The use of kits not type-approved by the
manufacturer can not guarantee the obser-
vance of safety standards, in particular for
live parts.
The manufacturer declines all responsibility
for the use of non type-approved compo-
nents.
Assembly and any subsequent test-
ing operation must be carried out by
from the point of view of electric safety
and health rules.
DECALCIFIER
The machine is supplied without a decalci-
er.
In case of connection with a network, the
water of which is very hard, mount a decal-
cier.
Use decalciers, the capacity of which is
suitable for the actual use of the machine.
In case of supply from the tank, ltering
cartridges can be used.
The cartridges must be replaced at regular
intervals, according to the water quality and
the manufacturer's instructions.
Decalciers, even available as an acces-
sory, shall be regenerated or replaced ac-
cording to the manufacturer’s instructions at
regular intervals.