Command and Response Table for Matrix Switcher Commands (continued)
DTP CrossPoint 4K Series Matrix Switchers • Programming Guide 81
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Logo Commands
Logo on and off
Assign a logo to an output
E
E
X!
*
X2^
LOGO
}
LogoE
X!
*
X2^]
Assign logo
X2^
to output
X!
.
Example (DTP CrossPoint 108 4K):
E
E6*4LOGO
}
LogoE6*4
]
Assign logo 4 to output 6.
Unassign a logo
E
E
X!
*0LOGO
}
LogoE
X!
*0
]
Set output
X!
to output no logo.
View logo assignment
E
E
X!
LOGO
} X2^]
Logo
X2^
is assigned to output
X!
.
View all logo assignments
E
ELOGO
}
00
n
•
X2^
y
]
Up to four (n) 00s, which are not scaled
outputs and up to four (y) 2-digit
X2^
s,
which are the logo status of scaler outputs.
RS-232 Insertion Commands
Captive screw and Ethernet serial port insertion enables
Enable an input captive screw serial
port insertion
E
I
X2@
*0LRPT
}
LrptI
X2@
*0
]
Enable the captive screw serial port insert,
on input
X2@
, disabling the Ethernet insert.
Enable an input Ethernet serial port
insertion
E
I
X2@
*1LRPT
}
LrptI
X2@
*1
]
Enable the Ethernet serial port insert on
input
X2@
, disabling the captive screw
serial port insert.
Set all RS-232 input insertions
E
I
X4#
*LRPT
}
LrptI
X4#]
View input insertion
E
I
X2@
LRPT
} X4#]
View all input insertions
E
ILRPT
} X4#
w
X4#
x
X4#
y
X4#
z
]
Two or four
X4#
s, depending on the
matrix size, one for each TP input.
Enable an output captive screw
serial port insertion
E
O
X!
*0LRPT
}
LrptO
X!
*0
]
Enable the captive screw serial port insert,
on output
X!
, disabling the Ethernet
insert.
Enable an output Ethernet serial port
insertion
E
O
X!
*1LRPT
}
LrptO
X!
*1
]
Enable the Ethernet serial port insert on
output
X!
, disabling the captive screw
serial port insert.
Set all RS-232 output insertions
E
O
X4#
*LRPT
}
LrptO
X4#]
View RS-232 output insertion
E
O
X!
LRPT
} X4#]
View all output insertions
E
OLRPT
} X4#
w
X4#
x
X4#
y
X4#
z
]
Two or four
X4#
s, depending on the
matrix size, one for each TP output.
Ethernet insertion serial port insert parameters
Set serial port parameters
EX4$
*
X4%
,
X4^
,
X4&
,
X4*
CP
}
Cpn
X4$
•Ccp
X4%
,
X4^
,
X4&
,
X4*]
Read serial port parameters
EX4$
CP
}
X4%
,
X4^
,
X4&
,
X4*]
Configure current port timeout
E
0*
X4(
TC
}
Pti0*
X4(]
Read current port timeout
E
0TC
} X4(]
Configure global IP port timeout
E
1*
X4(
TC
}
Pti1*
X4(]
Read global IP port timeout
E
1TC
} X4(]
Set UART starting point
EX5)
MD
}
Pmd
X5)]
Sets the initial (lowest) port number for
the range of numbers assigned to the
serial port and UARTs.
Read UART starting point
E
MD
} X5)]
NOTE: X! = TP (scaled) and insertion output number See X! definition on page 69 for numbers by matrix size.
X2@ = TP and insertion input number See X2@
definition
on page 69 for numbers by matrix size.
X2^ = Logo number 01
–
16
X4#
= Captive screw or UART 0 = Captive screw RS-232 insert (default) 1 = Ethernet RS-232 insert (UART)
X4$ = Port number See X4$ definition on page 69 for numbers by matrix size.
X4% = Baud rate 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200,
28800, 38400, 57600, 115200 (default=9600)
X4^ = Parity odd, even, none, mark, space (only the first letter required) (n = default)
X4& = Data bits 7, 8
X4* = Stop bits 1, 2
X4( = Port timeout (in 10-sec. increments) 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
X5) = UART starting point (see X5) on page 70) The starting point (X5)) is the rear panel Remote RS-232 port.
The next positions (X5)
+1
through X5)
x
) are DTP inputs.
The next positions (X5)
x+1
through X5)
y
) are DTP outputs.