DTP CrossPoint 84 Series Matrix Switchers • Operation 36
Recalling Presets
A full or partial configuration, plus all signal processor settings can be saved as one of 32
presets. Presets are created via the DSP Configurator software only (see Save a preset
on page105). When a preset is retrieved from memory, it becomes either the current
configuration or part of the current configuration, with all of the associated saved audio
settings.
Presets 1 through 12 are assigned to the input buttons and output buttons and can be
recalled from the front panel (see figure22). Preset numbers 12 through 32 can be recalled
via RS-232, USB, or Ethernet control only.
NOTES:
Presets cannot be viewed from the front panel unless they are recalled as the
current configuration.
The current configuration and all presets are stored in non-volatile memory. When
power is removed and restored, the current configuration is still active and all
presets are retained.
When a preset is recalled, it replaces all or part of the current configuration, which
is lost unless it is also stored as a preset. The recalled preset overwrites current
configuration ties in favor of the preset configuration ties.
Input
buttons
Output
buttons
Preset
1
Preset
6
Preset
7
Preset
3
Preset
8
Preset
4
Preset
5
Preset
2
Preset
9
Preset
11
Preset
12
Preset
10
1
2
3
4
1
2
3
4
5
6
7
8
INPUTS
OUTPUTS
Figure 22. DTP CrossPoint 84 Preset Locations
Example 5: Recalling a preset
In the following example, a preset is recalled to become the current configuration. The steps
show the front panel indications that result from your action.
1. Clear all selections: Press and release the Esc button.
2. Select Recall Preset mode: Press and release the Preset button.
PRESET
1
2
3
4
8
INPU
Press and release the Preset button.
The Preset button lights.
All input buttons with assigned
presets light red.
Preset Assigned
No Preset Assigned
3. Select the preset: Press and release the input button or output button for the
desired preset.
C O N T R O L
PRESET
ENTER
ESCVIEW
1
2
3
4
8
INPU
The Enter button blinks to
indicate the need to recall
the preset.
Press the button.
The button blinks to indicate that this
preset number is selected but not recalled.
22