DTP CrossPoint 84 Series Matrix Switchers • Programming Guide 68
Port Specific and Communications Protocol SIS Commands
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Set administrator password
EX5)CA} Ipa•X5)]
Read administrator password
ECA} X5)]
Reset (clear) administrator password
E•CA} Ipa•]
Set user password
EX5)CU} Ipu•X5)]
Read user password
ECU} X5)]
Reset (clear) user password
E•CU} Ipu•]
NOTE: The factory configured passwords for all accounts on this device have been set to the device serial number. Passwords are case sensitive. If
the device is reset, the password will be the original password configuration.
Set serial port parameters
EX5!*X5@,X5#,X5$,X5%CP} CpnX5!•CcpX5@,X5#,X5$,X5%]
Read serial port parameters
EX5!CP} X5@,X5#,X5$,X5%]
Configure flow control
EX5!*Y8^,Y8&CF} CpnX5!•CY8^,Y8&]
Read flow control
EX5!CF} Y8^,Y8&]
Configure receive timeout
EX5!*Y8*,Y8(CE} CpnX5!•CceY8*,Y8(,Y9),Y9!]
NOTE: The configure command is sufficient as shown for most users, with the priority (Y9)) and length or delimiter (
Y9!
) omitted). The response in
this case is “CpnX5!•CceY8*,Y8(,0,00000L],” with the default Y9) and
Y9!
values returned.
Read receive timeout
EX5!CE} Y8*,Y8(,Y9),Y9!]
Set mode
EX5!*X5^CY} CpnX5!•CtyX5^]
Read mode
EX5!CY} X5^]
Set verbose mode
EX5&CV} VrbX5&]
Read verbose mode
ECV} X5&]
Configure current port timeout
E0*X5*TC} Pti0*X5*]
Read current port timeout
E0TC} X5*]
Configure global IP port timeout
E1*X5*TC} Pti1*X5*]
Read global IP port timeout
E1TC} X5*]
KEY: X5) = Password Up to 12 alphanumeric characters
NOTE: The HTML language reserves certain characters for specific functions (see Special Characters on page69).
X5! = Port number 01 = Remote (RS-232) port
X5@ = Baud rate 9600 (default), 19200, 38400, 115200
X5# = Parity odd, even, none, mark, space (only the first letter required) (n = default)
X5$ = Data bits 7, 8 (default)
X5% = Stop bits 1 (default), 2
NOTE: X5! through X5% and X5* are variables for the rear panel Remote RS-232 port. These variables are repeated on page 59 as X3( through
X4$ for the RS-232 inserts.
X5^ = Port type 0 = RS-232 (default) 1 = RS-422 (not available on DTP CrossPoint)
X5& = Verbose mode 0 = Clear or none (default for Telnet connection) 2 = Tagged responses for queries
1 = Verbose mode (default for RS-232 or USB connection) 3 = Verbose mode and tagged for queries
NOTE: If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command does (for
example, the read matrix name command
ECN}, returns Ipn•X2)]).
X5* = Port timeout interval (in 10-second increments) 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
Reset (clear) administrator password
Reset (clear) user password