DTP CrossPoint 84 Series Matrix Switchers • Programming Guide 67
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
RS-232 Insertion Commands
Captive Screw and Ethernet Serial Port Insertion Enables
Enable an input captive
screw serial port
insertion
EIX1&*0LRPT} LrptIX1&*0]
Enable the captive screw serial port insert
on input
X1&. This disables the Ethernet
RS-232 insert.
Enable an input
Ethernet serial port
insertion
EIX1&*1LRPT} LrptIX1&*1]
Enable the Ethernet serial port insert on
input
X1&. This disables the captive screw
serial port insert.
Set all RS-232 input
insertions
EIX3**LRPT} LrptIX3*]
View input insertion
EIX1&LRPT} X3*]
View all input insertions
EILRPT} X3*
7
X3*
8
] One X3* for both available inputs, starting
at input 7.
Enable an output
captive screw serial port
insertion
EOX1(*0LRPT} LrptOX1(*0]
Enable the captive screw serial port insert
on output
X1(. This disables the Ethernet
serial port insert.
Enable an output
Ethernet serial port
insertion
EOX1(*1LRPT} LrptOX1(*1]
Enable the Ethernet serial port insert on
output
X1(. This disables the captive
screw serial port insert.
Set all RS-232 output
insertions
EOX3**LRPT} LrptOX3*]
View RS-232 output
insertion
EOX1(LRPT} X3*]
View all output
insertions
EOLRPT} X3*
3
X3*
4
] One X3* for both available outputs,
starting at output 3.
Ethernet and Serial Port Insert Parameters
Set serial port parameters
EX3(*X4),X4!,X4@,X4#CP}
CpnX3(CcpX4),X4!,X4@,X4#]
Read serial port
parameters
EX3(CP}
X4),X4!,X4@,X4#]
Configure current port
timeout
E0*X4$TC} Pti0*X4$]
Read current port
timeout
E0TC} X4$]
Configure global IP port
timeout
E1*X4$TC} Pti1*X4$]
Read global IP port
timeout
E1TC} X4$]
Set UART start point
EX4%MD} PmdX4%]
Sets the initial (lowest) port number for the
range of numbers assigned to the serial
port and UARTs.
Read UART start point
EMD} X4%]
KEY: X3( = Port number 01 = Remote (RS-232) port 0205 = UARTs 1 — 5 (DTP input and output ports)
X4) = Baud rate 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 115200
(default=9600)
X4! = Parity odd, even, none, mark, space (only the first letter required) (n = default)
X4@ = Data bits 7, 8
X4# = Stop bits 1, 2
X4$ = Port timeout interval (in 10-second increments) 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
X4% = UART starting point The starting point (X4%) is the rear panel Remote RS-232 port.
The next two positions (X4%
+1
and X4%
+2
) are DTP inputs.
The next two positions (X4%
+3
and X4%
+4
) are DTP outputs.
Default values: 2000 = Rear panel Remote (RS-232) port 2003 and 2004 = Output 3 and output 4
2001 and 2002 = Input 7 and input 8