SMP 111 • Remote Communication and Control 71
Error Responses
When the SMP is unable to execute the command, it returns an error response to the host.
The error response codes and their descriptions are as follows:
E10
Unrecognized command
E18
System timed out
E12
Invalid port number
E22
Busy
E13
Invalid parameter (number is out of
range)
E24
Privilege violation
E14
Not valid for this configuration
E26
Maximum connections exceeded
E17
Invalid command for signal type
E28
Bad file name or file not found
Using the Command and Response Tables
The Command and Response Tables begins on page 75. Symbols used in the table
represent variables in the command and response fields. Command and response examples
are shown throughout the table. The SIS commands are not case sensitive. The ASCII to
HEX conversion table below is for use with the command and response table.
ASCII to Hex Conversion Table
Space
Figure 63. ASCII to Hex Conversion
figure 63

Table of Contents

Other manuals for Extron electronics SMP 111

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics SMP 111 and is the answer not in the manual?

Extron electronics SMP 111 Specifications

General IconGeneral
BrandExtron electronics
ModelSMP 111
CategoryTV Tuner
LanguageEnglish