Chapter 6 Fastening Operation
PAGE 6-52
D-No.309 Message Block Byte Length [byte] (Fieldbus only)
The programmed message block byte length of the fieldbus set in the controller is indicated.
Fieldbus type
CC-Link
DeviceNet
PROFIBUSDP-V1
PROFINET IO
EtherNet/IP
144byte
250 byte
64 byte
250 byte
250 byte
D-No.310 Message Setting Byte Length “PLC HFC3000 [byte] (Fieldbus only)
The programmed message setting byte length for “PLC HFC3000” of the installed fieldbus is
indicated.
D-No.311 Message Setting Byte Length HFC3000 PLC” [byte] (Fieldbus only)
The programmed message setting byte length for HFC3000 PLC” of the installed
fieldbus is indicated.
D-No.312 IP Address (upper 6 digits) D-No.313 IP Address (lower 6 digits)
Setting range: 0 ~ 255 (PROFINET IO, EtherNet/IP)
The programmed IP address of the installed fieldbus is indicated.
D-No.314 Subnet Mask (upper 6 digits) D-No.315 Subnet Mask (lower 6 digits)
Setting range: 0 ~ 255 (PROFINET IO, EtherNet/IP)
The programmed subnet mask of the installed fieldbus is indicated.
D-No.316 Gateway (upper 6 digits) D-No.317 Gateway (lower 6 digits)
Setting range: 0 ~ 255 (PROFINET IO, EtherNet/IP)
The programmed gateway of the installed fieldbus is indicated.