FT-70 Fill Level Inspector Service Manual
8-24
Caution
The board and generator are a matched set and must be replaced
as a unit. If you do not replace both the components together,
damage to the FT-70 could result.
7. Replace the power supply board insulator with the new
insulator provided in the replacement kit and install the new
power supply board.
8. Install the new generator insulator that is provided in the
replacement kit and carefully insert the new generator unit into
the FT-70. Be sure the holes in the generator, insulator and heat
sink align.
Figure 8-6. Insert the new generator unit.
1
2
3
4
5
6
No. Description
1 Generator
2 Generator Insulator
3 Power Supply Board
4 Power Cable
5 Connector PX-1
6 Power Supply Board Insulator
Industrial Dynamics Company, Ltd. © 40256-0600