Maintenance and care
153
15.10.2 Checking the fluid level and filling with SEALIT
• Check the fluid level in the sealer regularly.
Make sure the sealer is always filled at least
to the “min” mark to prevent the felts from
drying up. When felts with glue residues dry
up they harden to the point of becoming
prematurely useless.
Filling with sealing fluid
We recommend using the SEALIT sealing
fluid. This special sealing fluid is available
from FP or an authorized FP dealer.
• Swing the filler hole lid aside.
• Fill the sealer with SEALIT sealing fluid.
• Check the fluid level. The fluid level in the
sealer should roughly reach to the “max”
mark.
• Swing the filler hole lid back on.
• If necessary: dry the sealer outside.
Fluid level
gauge
Filler hole