EasyManua.ls Logo

Fuji Electric Faldic-a RYS-R Series - Page 23

Fuji Electric Faldic-a RYS-R Series
291 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHT260a (Engl.)2-13
(2) Basic specification for 100 [V] class input voltage of amplifier
0.05 to 0.2 [kW]
Amplifier type RYS□□□S3-RPS6 500 101 201
Applicable motor output (*1) [kW] 0.05 0.1 0.2
Phase, freq. Single-phase for power supply, for control, 50/60 [Hz]Input
Voltage 100 to 115 [V], +10 to 15%
System Sinusoidal wave PWM current control (all digital)
Carrier freq. [kHz] 10
Feedback 16-bit serial encoder (one-rotation resolution 16 bit, multiple-rotation 16 bit)
Loading for 0 to 100% deviation
Supply volt.
±1 [r/min]
max.
For 10 to +10% fluctuation
Speed
control
accuracy
Amb. temp. ±0.2% max. for 25°C±10% variation (at analog volt. input)
Speed range 1 : 5000 (at rated load)
Freq. response 600 [Hz] (at J
L
= J
M
(*2) )
Load inertia. max. 100 times of the motor rotor inertia, permissible
Control
data
Overload capability 300% for approx. 3 [s]
Braking Regenerating, dynamic with external braking resistor
Protection OC (output overcurrent), OS (overspeed), L
V
(low voltage, undervoltage),
H
V
(high voltage, overvoltage), Et (encoder trouble), Ct (circuit trouble, amplifier trouble),
dE (data error, memory error), CE (combination error), rH
2
(resistor heat 2),
EC (encoder communication error), CtE (cont (control signal) error),
OL (motor overload), rH (resistor heat, braking (OB) resistor overheat),
OF (over flow, deviation excessive), AH (amp. heat, amplifier overheat),
EH (encoder heat, encoder overheat), AL (absolute data lost),
AF (absolute data over flow)
Function
Display, setting CHARGE (red), 7-segment LED with 5 digit and 4 operation keys
Install location For indoors, 1000 [m] and below of site-altitude, under clean atmosphere,
no explosive hazardous gas and vapour is existing.
In the case of compliance with the European standard :
Pollution degree = 2, Over voltage category =
Temp., humidity 10 to +55°C, 90% RH max. (no condensation)
Ambient
condition
Vibration / shock 4.9 [m/s
2
] / 19.6 [m/s
2
] acceleration, acceptable (max.)
Others DC reactor terminals (P1, P+) for harmonics suppression.
UL/cUL (compliance with UL508), European standards (compliance with EN50178)
Mass (weight) [kg] 0.9 1.2
(*1) Use amplifier and motor as a specified pair of typesFor example, RYS500 type amplifier can be combined with the acceptable
GYS500 type motor only.
(*2) Moment of inertia
J
L
: Moment of load inertia after conversion into motor shaft extension
J
M
: Moment of inertia of motor rotor

Table of Contents