3.4 Programming Mode
3-24
Table 3.4-4 Running status 2 (3_23) bit assignment
Bit
Symbol
Content
Bit
Symbol
Content
15
-
Drive motor type
0000: induction motor
1000: synchronous motor
7
-
Speed limiting (under torque
control)
14
6
-
(Not used)
13
5
-
Motor selection
00: Motor 1
01: Motor 2
10: Motor 3
11: Motor 4
12
4
11
-
(Not used)
3
-
Control method
0000: V/f control without slip
compensation inactive
0001: Dynamic torque vector
control
0010: V/f control with slip
compensation active
0011: V/f control with sensor
0100: Dynamic torque vector
control with sensor
0101: Sensorless vector control
0110: Vector control for IM with
sensor
1010: Torque control (sensorless
vector control)
1011: Torque control (vector
control with sensor)
10
2
9
1
8
0
Table 3.4-5 Running status display example
LED No.
LED 4
LED 3
LED 2
LED 1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Symbol
BUSY
WR
RL
ALM
DEC
ACC
IL
VL
TL
NUV
BRK
INT
EXT
REV
FWD
Binary
1
0
0
0
0
0
1
1
0
0
1
0
0
0
0
1
Display
example
Hexadecimal
on the LED
monitor
Table 3.4-6 Running status display example
(Synchronous motor assigned to motor 4, motor running under vector control with sensor)
LED No.
LED 4
LED 3
LED 2
LED 1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Symbol
-
-
-
-
-
-
Binary
1
0
0
0
0
0
0
0
0
0
1
1
0
1
1
0
Display
example
Hexadecimal
on the LED
monitor