3.6 USB Port
3-47
OPERATION USING THE KEYPAD
3.6 USB Port
There is a USB cable connection port (miniB) on the front of the keypad. To connect the USB cable, open the
connection port cover and connect the cable as shown below.
Connect the inverter directly to a PC with the USB cable. FRENIC Loader allows the user to edit, check, and manage
inverter function codes, and perform remote operations such as monitoring data while the inverter is running, and
starting and stopping the inverter. The running status and alarms, etc. can also be monitored.
Refer to the “FRENIC Loader Instruction Manual” for details on how to use FRENIC Loader.
Furthermore, the keypad can be temporarily used as memory media. Write the inverter running status to the keypad,
disconnect the keypad, and then connect it to a PC with the USB cable at a location other than the workplace such
as an office. Function code data and the inverter running status read can be edited, set, and checked with FRENIC
Loader.
Refer to section “3.4.8 Copying data” for details on saving data
USB connection port cover