4.8 Configuring Function Codes for Drive Controls
4-13
4.8 Configuring Function Codes for Drive Controls
The relation of the motor control method, motor selection and motor parameter setting is shown in Figure 4.8 1. It is
necessary to change the motor parameter setting depending on the driven motor.
Fig.4.8-1
Set PG-related function
codes d14, d15, d16,
and d17.
[3] V/f control with slip
compensation (F42* = 2),
dynamic torque vector
control
(F42* = 1),
Sensorless vector
control
(F42* = 5)
[4] Dynamic torque
vector control with
sensor
(F42* = 4)
Vector control
with sensor
(F42* = 6)
∙ Motors of other companies
∙ Non-standard motors
∙ Motors of other companies
∙ Non-standard motors
Basic settings
Set F03*, F04*, F05*, F07,
F08, F09*,
P01*, P02*, and P03*.
[1] V/f control
(F42* = 0)
[2] V/f control with
sensor
(F42* = 3)
Set PG-related function
codes d14, d15, d16,
and d17.
∙ Fuji standard motors
∙ Motors of other companies
∙ Non-standard motors
∙ Fuji standard motors
∙ Motors of other companies
∙ Non-standard motors
(1) Set P99* (motor 1 selection).
(2) Set F03*, F04*, F05*, F07, F08,
P01*, P02*, and P03*.
(3) Perform tuning for
sensorless vector control.
(1) Set 4 (other) for P99* (motor 1
selection).
(2) Set F03*, F04*, F05*, F07, F08,
P01*, P02*, and P03*.
(3) Perform tuning.
(1) Set P99* (motor 1 selection).
(2) Set F03*, F04*, F05*, F07, F08,
P01*, P02*, and P03*.
(1) Set 4 (other) for P99*
(motor 1 selection).
(2) Set F03*, F04*, F05*, F07, F08,
P01*, P02*, and P03*.
(3) Perform tuning.
Electronic thermal
overload relays
(for motor protection)
Set F10, F11, and F12.
Or specify protection
with a PTC/NTC
thermistor.
[1] Sensorless
vector control
(F42* = 15)
[2] Vector control
with sensor
(F42* = 16)
Set PG-related
function codes
d14 and d15.
Fuji GNB2, GNP1 series
synchronous motors
(IPM)
Other synchronous motors
(IPM, SPM)
Fuji GNF2 series
synchronous motors (IPM)
Other synchronous motors
(IPM, SPM)
(1) Set 21 (GNB2) or 23
(GNP1) for P99* (motor 1
selection).
(2) Set F03*, F07, F08, P01*,
P02*, P03*, and P30*.
(1) Set 20 (other PM) for P99*
(motor 1 selection).
(2) Set F03*, F04*, F05*, F07,
F08, P01*, P02*, P03*,
P30*, and P90*.
(3) Perform tuning.
(1) Set 22 (GNF2) for P99*
(motor 1 selection).
(2) Set F03*, F07, F08, P01*,
P02*, P03*, and P30*.
Motor related
parameter settings
PG sensor
related settings
(1) Set 20 (other PM) for P99*
(motor 1 selection).
(2) Set F03*, F04*, F05*, F07,
F08, P01*, P02*, P03*,
P30*, and P90*.
(3) Perform tuning.
Motor protection
settings