5.3 Description of Function Codes 5.3.1 F codes (Fundamental functions)
5-81
FUNCTION CODES
Chap 5
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
Forward rotation/reverse rotation selection “DIR”
Only when F02 = 1 external signal, it is possible to change the run command direction with the “forward
rotation/reverse rotation “DIR” signal assigned to the digital input terminal.
Input signal “DIR”
“FWD”
“REV”
Run command direction
OFF
ON
OFF
Forward rotation
ON
ON
OFF
Reverse rotation
OFF
OFF
ON
Reverse rotation
ON
OFF
ON
Forward rotation
Not required
ON
ON
Stop command
Self-hold selection “HLD”
Self-hold can be applied to “FWD” and “REV” with the “Self-hold selection “HLD”” signal assigned to the digital input
terminal. When “HLD” is ON, the inverter self-holds the “FWD” or “REV” signal, and when OFF, the hold state is
released.
2-wire operation
Two types of 2-wire operation can be configured regardless of whether “DIR” is used.
2-wire operation (1)
2-wire operation (2)
正転
逆転
[FWD]
[REV]
[CM]
運転/
停止
正転/
逆転
[FWD]
[DIR]
[CM]
Forward rotation/stop: [FWD]
Reverse rotation/stop: [REV]
Run/stop: [FWD]
Forward rotation/reverse rotation: [DIR]
Output
frequency
Forward
rotation
Reverse
rotation
Ignored
Forward
rotation
Reverse
rotation
Run/
stop
Forward
rotation/
reverse
rotation

Table of Contents