EasyManua.ls Logo

Fuji Electric FRENIC MEGA G2 Series - Chapter 5 FUNCTION CODES

Fuji Electric FRENIC MEGA G2 Series
970 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5
FUNCTION CODES
This chapter explains the table of function codes used in FRENIC-MEGA, index per purpose, and the detail of each
function code.
Contents
5.1 Function Codes Overview ························································································ 5-1
5.2 Function Code Tables ····························································································· 5-2
5.2.1 Supplementary note ························································································ 5-2
5.2.2 Function code tables ······················································································· 5-4
[ 1 ] F codes: Fundamental functions ········································································ 5-4
[ 2 ] E codes: Extension Terminal Functions (terminal functions) ····································· 5-8
[ 3 ] C codes: Control Functions of Frequency (Control function) ··································· 5-16
[ 4 ] P codes: Motor 1 Parameters (Motor 1 parameters) ·············································· 5-18
[ 5 ] H codes: High Performance Functions (High level functions) ·································· 5-20
[ 6 ] A codes: Motor 2 Parameters (Motor 2 parameters) ·············································· 5-26
[ 7 ] b codes: Motor 3 Parameters (Motor 3 parameters) ·············································· 5-29
[ 8 ] r codes: Motor 4 Parameters (Motor 4 parameters) ··············································· 5-31
[ 9 ] J codes: Application Functions 1 (Application function 1) ········································ 5-33
[ 10 ] d codes: Application Functions 2 (Application functions 2) ······································ 5-36
[ 11 ] U codes: Application Functions 3 (Customizable logic) ·········································· 5-43
[ 12 ] y codes: LINK Functions (Link functions) ···························································· 5-48
[ 13 ] o codes: Option Functions (Option functions) ······················································ 5-50
[ 14 ] K codes: Keypad functions (Keypad functions) ···················································· 5-53
5.3 Description of Function Codes ················································································· 5-66
5.3.1 F codes (Fundamental functions) ······································································ 5-66
[ 1 ] Setting the frequency with the keypad (F01 = 0 (factory default) or 8) ······················· 5-68
[ 2 ] Setting the frequency with analog input (F01 = 1 to 3, 5, 6) ····································· 5-69
[ 3 ] Frequency setting by digital input signal “UP”/“DOWN” (F01=7) ······························· 5-76
[ 4 ] Frequency setting using digital input (option DIO interface card) (F01 = 11) ··············· 5-77
[ 5 ] Frequency setting using pulse train input (F01 = 12) ············································· 5-78
5.3.2 E codes (Extension terminal functions) ···························································· 5-136
5.3.3 C codes (Control functions) ··········································································· 5-190
5.3.4 P codes (Motor 1 parameters) ········································································ 5-201
5.3.5 H codes (High performance functions) ····························································· 5-212
[ 1 ] Measuring the capacitance of DC link bus capacitor in comparison
with initial one at shipment ············································································ 5-233

Table of Contents

Related product manuals