5.3 Description of Function Codes 5.3.1 F codes (Fundamental functions)
5-124
H75
Applicable quadrant
2: Upper limit/
lower limit
Limiting is applied by separating limit values into the upper limit value (torque limiter
A) and the lower limit value (torque limiter B).
Limiting is applied in the following patterns depending on the polarity of torque limiter
A and torque limiter B
Table 5.3-2
Torque limit value A
Torque limit value B
Pattern 1
Plus
Plus
Pattern 2
Plus
Minus
Pattern 3
Minus
Minus
Pattern 1
Pattern 2
Pattern 3
If torque limiter A < torque limiter B, limiting is fixed with torque limiter A.
By setting an upper limit/lower limit for torque limiting, reciprocating vibrations
may occur between the upper limit value and lower limit value depending on
conditions such as a narrowing in the width of the upper limit/lower limit setting
value, or a delay in the speed control system response, and therefore caution is
advised.