5.3 Description of Function Codes 5.3.1 F codes (Fundamental functions)
5-123
FUNCTION CODES
Chap 5
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
Torque limiter (Applicable quadrant) (H75)
The settings for each quadrant (forward rotation drive/braking, reverse rotation drive/braking) for which torque limiter
A and B are enabled can be selected from “Drive/braking torque limiter”, “4 identical quadrants torque limiter”, and
“Upper limit/lower limit torque limiter” shown below.
H75
Applicable quadrant
0: Drive/
braking
Limiting is applied by separating torque limiting when driving (torque limiter A) and
torque limiting when braking (torque limiter B) for both forward rotation and reverse
rotation.
1: 4 identical
quadrants
Limiting is applied with the same limiting value (torque limiter A) for both
forward/reverse rotation and driving/braking.