C20
Jogging frequency
Related function codes: H54 and H55 Acceleration/Deceleration time (Jogging)
H54 and H55 Acceleration/Deceleration time (jogging)
d09 to d13 Speed control (JOG)
C20 specifies the operating condition (frequency) to apply in jogging operation.
FUNCTION CODES
Data setting range
Description
C20
Jogging frequency
0.00 to 599.0 (Hz)
Reference frequency for jogging
operation
H54
Acceleration time (Jogging)
0.00 to 6000 s
Acceleration time for jogging
operation
H55
Deceleration time (Jogging)
0.00 to 6000 s
Deceleration time for jogging
operation
d09
Speed control (JOG)
Speed command filter
0.000 to 5.000s
Speed control system adjustment
element when performing jogging
operation under speed sensorless
vector control/vector control with
speed sensor
See d01 to d06 for adjustment
method.
d10
Speed control (JOG)
Speed detection filter
0.000 to 0.100s
d11
Speed control (JOG) P gain
0.1 to 200.0 times
d12
Speed control (JOG) I integral
time
0.001 to 1.000s
d13
Speed control (JOG) Output
filter
0.000 to 0.100s
For details about jogging operation, refer to Chapter 3 “3.3.6 Jogging operation.”