5.3 Description of Function Codes 5.3.5 H codes (High performance functions)
5-244
Table 5.3-17 Warning selection 3 (H83), bit assignment of selectable factors
Bit
Symbol
Content
Bit
Symbol
Content
15
-
-
7
-
-
14
rAF
Cooling capability drop warning
6
-
-
13
iGb
IGBT lifetime alarm
5
-
-
12
-
-
4
Ca5
User-defined alarm 5
11
-
-
3
Ca4
User-defined alarm 4
10
-
-
2
Ca3
User-defined alarm 3
9
-
-
1
Ca2
User-defined alarm 2
8
-
-
0
Ca1
User-defined alarm 1
Table 5.3-18 Display of warning factors
(Example) Warning factors “RS-485 communications error (COM port 2),” “RS-485 communications error (COM
port 1),” “Option communications error,” “Overload of motor 1” and “Cooling fin overheat” are selected
by H81.
LED No.
LED 4
LED 3
LED 2
LED 1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Symbol
-
-
er
p
er
8
er
5
er
4
-
0l
4
0l
3
0l
2
0l1
dbH
-
0H3
OH2
0H1
Display example
Binary
0
0
1
1
0
1
0
0
0
0
1
0
0
0
0
1
Hexadeci
mal
* Refer to
Table
5.3-19.
3
4
2
1
Hexadeci
mal on
the LED
monitor

Table of Contents